Inspection
At JASO Industrial Cranes we guarantee maximum security and compliance with the strictest regulations.
Our extensive experience and ability to innovate has allowed us to develop a wide range of explosion-proof solutions complying with the European ATEX regulations, directives 94/9/EC and 2006/42/EC. All JASO ATEX products are certified by the following technical studies housed at the LOM official laboratory:
An explosion could occur if a combustible material makes contact with the air together with an ignition source. The JASO – ATEX products prevent this source of explosions with their exclusive design and technology. Our products are designed for working safely in flammable atmospheres in the petrochemical industry, refineries, electric power stations and, ultimately, in any type of industry where an explosion of this type could occur.
ATEX CODE COMPOSITION FOR EQUIPMENT | JASO ATEX | FINAL EQUIPMENT MARKING | ||||||
---|---|---|---|---|---|---|---|---|
ZONE | GROUP | CATEGORY | GAS (G) / DUST (D) | SUBGROUP | MAX SURFACE TEMPERATURE | |||
T ºC | TEMP CODE (T1…T6) | |||||||
1 | II | 2 | G | IIA | 450 | T1 | YES | II 2G ck T1 (450º) |
300 | T2 | YES | II 2G ck T2 (300º) | |||||
200 | T3 | YES | II 2G ck T3 (200º) | |||||
135 | T4 | * | II 2G ck T4 (135º) | |||||
IIB | 450 | T1 | YES | II 2G ck T1 (450º) | ||||
300 | T2 | YES | II 2G ck T2 (300º) | |||||
200 | T3 | YES | II 2G ck T3 (200º) | |||||
135 | T4 | * | II 2G ck T4 (135º) | |||||
2 | II | 3 | G | IIA | 450 | T1 | YES | II 2G ck T1 (450º) |
300 | T2 | YES | II 2G ck T2 (300º) | |||||
200 | T3 | YES | II 2G ck T3 (200º) | |||||
135 | T4 | * | II 2G ck T4 (135º) | |||||
IIB | 450 | T1 | YES | II 2G ck T1 (450º) | ||||
300 | T2 | YES | II 2G ck T2 (300º) | |||||
200 | T3 | YES | II 2G ck T3 (200º) | |||||
135 | T4 | * | II 2G ck T4 (135º) | |||||
21 | II | 2 | D | IIIA | 450 | T1 | YES | II 2GD ck IIB/IIIC T1 (450º) |
300 | T2 | YES | II 2GD ck IIB/IIIC T2 (300º) | |||||
200 | T3 | YES | II 2GD ck IIB/IIIC T3 (200º) | |||||
135 | T4 | * | II 2GD ck IIB/IIIC T4 (135º) | |||||
IIIB | 450 | T1 | YES | II 2GD ck IIB/IIIC T1 (450º) | ||||
300 | T2 | YES | II 2GD ck IIB/IIIC T2 (300º) | |||||
200 | T3 | YES | II 2GD ck IIB/IIIC T3 (200º) | |||||
135 | T4 | * | II 2GD ck IIB/IIIC T4 (135º) | |||||
IIIC | 450 | T1 | YES | II 2GD ck IIB/IIIC T1 (450º) | ||||
300 | T2 | YES | II 2GD ck IIB/IIIC T2 (300º) | |||||
200 | T3 | YES | II 2GD ck IIB/IIIC T3 (200º) | |||||
135 | T4 | * | II 2GD ck IIB/IIIC T4 (135º) | |||||
22 | II | 3 | D | IIIA | 450 | T1 | YES | II 2GD ck IIB/IIIC T1 (450º) |
300 | T2 | YES | II 2GD ck IIB/IIIC T2 (300º) | |||||
200 | T3 | YES | II 2GD ck IIB/IIIC T3 (200º) | |||||
135 | T4 | * | II 2GD ck IIB/IIIC T4 (135º) | |||||
IIIB | 450 | T1 | YES | II 2GD ck IIB/IIIC T1 (450º) | ||||
300 | T2 | YES | II 2GD ck IIB/IIIC T2 (300º) | |||||
200 | T3 | YES | II 2GD ck IIB/IIIC T3 (200º) | |||||
135 | T4 | * | II 2GD ck IIB/IIIC T4 (135º) | |||||
IIIC | 450 | T1 | YES | II 2GD ck IIB/IIIC T1 (450º) | ||||
300 | T2 | YES | II 2GD ck IIB/IIIC T2 (300º) | |||||
200 | T3 | YES | II 2GD ck IIB/IIIC T3 (200º) | |||||
135 | T4 | * | II 2GD ck IIB/IIIC T4 (135º) |