Our extensive experience and ability to innovate has allowed us to develop a wide range of explosion-proof solutions complying with the European ATEX regulations, directives 94/9/EC and 2006/42/EC. All JASO ATEX products are certified by the following technical studies housed at the LOM official laboratory:

  • JASO-CP01-14-EX for HOISTS - LOM 14 ATEX 0030*
  • JASO-PG01-14-EX for EOT CRANES - LOM 14 ATEX 0031*

An explosion could occur if a combustible material makes contact with the air together with an ignition source. The JASO – ATEX products prevent this source of explosions with their exclusive design and technology. Our products are designed for working safely in flammable atmospheres in the petrochemical industry, refineries, electric power stations and, ultimately, in any type of industry where an explosion of this type could occur.

Download ATEX Solutions catalog

ATEX CODE COMPOSITION FOR EQUIPMENT JASO ATEX FINAL EQUIPMENT MARKING
ZONE GROUP CATEGORY GAS (G) / DUST (D) SUBGROUP MAX SURFACE TEMPERATURE
T ºC TEMP CODE (T1…T6)
1 II 2 G IIA 450 T1 YES II 2G ck T1 (450º)
300 T2 YES II 2G ck T2 (300º)
200 T3 YES II 2G ck T3 (200º)
135 T4 * II 2G ck T4 (135º)
IIB 450 T1 YES II 2G ck T1 (450º)
300 T2 YES II 2G ck T2 (300º)
200 T3 YES II 2G ck T3 (200º)
135 T4 * II 2G ck T4 (135º)
2 II 3 G IIA 450 T1 YES II 2G ck T1 (450º)
300 T2 YES II 2G ck T2 (300º)
200 T3 YES II 2G ck T3 (200º)
135 T4 * II 2G ck T4 (135º)
IIB 450 T1 YES II 2G ck T1 (450º)
300 T2 YES II 2G ck T2 (300º)
200 T3 YES II 2G ck T3 (200º)
135 T4 * II 2G ck T4 (135º)
21 II 2 D IIIA 450 T1 YES II 2GD ck IIB/IIIC T1 (450º)
300 T2 YES II 2GD ck IIB/IIIC T2 (300º)
200 T3 YES II 2GD ck IIB/IIIC T3 (200º)
135 T4 * II 2GD ck IIB/IIIC T4 (135º)
IIIB 450 T1 YES II 2GD ck IIB/IIIC T1 (450º)
300 T2 YES II 2GD ck IIB/IIIC T2 (300º)
200 T3 YES II 2GD ck IIB/IIIC T3 (200º)
135 T4 * II 2GD ck IIB/IIIC T4 (135º)
IIIC 450 T1 YES II 2GD ck IIB/IIIC T1 (450º)
300 T2 YES II 2GD ck IIB/IIIC T2 (300º)
200 T3 YES II 2GD ck IIB/IIIC T3 (200º)
135 T4 * II 2GD ck IIB/IIIC T4 (135º)
22 II 3 D IIIA 450 T1 YES II 2GD ck IIB/IIIC T1 (450º)
300 T2 YES II 2GD ck IIB/IIIC T2 (300º)
200 T3 YES II 2GD ck IIB/IIIC T3 (200º)
135 T4 * II 2GD ck IIB/IIIC T4 (135º)
IIIB 450 T1 YES II 2GD ck IIB/IIIC T1 (450º)
300 T2 YES II 2GD ck IIB/IIIC T2 (300º)
200 T3 YES II 2GD ck IIB/IIIC T3 (200º)
135 T4 * II 2GD ck IIB/IIIC T4 (135º)
IIIC 450 T1 YES II 2GD ck IIB/IIIC T1 (450º)
300 T2 YES II 2GD ck IIB/IIIC T2 (300º)
200 T3 YES II 2GD ck IIB/IIIC T3 (200º)
135 T4 * II 2GD ck IIB/IIIC T4 (135º)